3-21
Catalyst 6500 Series Switch Module Installation Guide
78-15725-02
Chapter 3 Installing the Module
Verifying the Installation
Mod Sub-Type Sub-Model Sub-Serial Sub-Hw
--- ----------------------- ------------------- ----------- ------
1 L3 Switching Engine WS-F6K-PFC SAD03365068 1.0
Console>
This example shows the output of the show port command:
Console> show port 1/1
Port Name Status Vlan Duplex Speed Type
----- ------------------ ---------- ---------- ------ ----- ------------
1/1 connected 1 full 1000 1000BaseSX
Port Security Secure-Src-Addr Last-Src-Addr Shutdown Trap IfIndex
----- -------- ----------------- ----------------- -------- -------- -------
1/1 disabled No disabled 3
Port Broadcast-Limit Broadcast-Drop
-------- --------------- --------------------
1/1 - 0
Port Send FlowControl Receive FlowControl RxPause TxPause
admin oper admin oper
----- -------- -------- -------- -------- ---------- ----------
1/1 desired on off off 0 0
Port Status Channel Admin Ch Neighbor Neighbor
Mode Group Id Device Port
----- ---------- --------- ----- ----- ----------------------------------- -----
1/1 connected auto 123 0
Port Align-Err FCS-Err Xmit-Err Rcv-Err UnderSize
----- ---------- ---------- ---------- ---------- ---------
1/1 0 0 0 0 0
Port Single-Col Multi-Coll Late-Coll Excess-Col Carri-Sen Runts Giants
----- ---------- ---------- ---------- ---------- --------- --------- ---------
1/1 0 0 0 0 23 0 0
Last-Time-Cleared
--------------------------
Fri March 2 2003, 20:41:52
Console>