Fiber-Optic Connectors
Always make sure that you insert the connector completely into the socket. This 
action is especially important when you are making a connection between a 
module and a long distance (1.24 miles [2 kilometers]) or a suspected highly 
attenuated network. If the link LED does not light, try removing the network cable 
plug and reinserting it firmly into the module socket. It is possible that enough dirt 
or skin oils have accumulated on the plug faceplate (around the optical-fiber 
openings) to generate significant attenuation, reducing the optical power levels 
below threshold levels so that a link cannot be made. 
Caution Use extreme care when removing or installing connectors so that you do not 
damage the connector housing or scratch the end-face surface of the fiber. Always 
install protective covers on unused or disconnected components to prevent 
contamination. Always clean fiber connectors before installing them.
For fiber-optic connector cleaning instructions, refer to the “Cleaning the 
Fiber-Optic Connectors” section on page B-17.
MT-RJ Connectors
Warning
Invisible laser radiation may be emitted from disconnected fibers or 
connectors. Do not stare into beams or view directly with optical instruments. 
Statement 1051
The MT-RJ style connector is used on fiber-optic modules to increase port density. 
(See Figure B-7.)