parameters. To add the ANS parameters, see the DLP-G541 Adding an ANS Parameter, on page 14 task for
instructions.
Step 6 Click the value of the ANS parameter that you want to modify and enter the new value specified in the
following table. To modify the ANS parameters, see the DLP-G681 Modifying an ANS Parameter, on page
15 task for instructions.
Table 2: Values for the ANS Parameters (amplifier)
ValueANS ParameterPort
35.0 dBmChannel LOS ThresholdSlot 16 (OPT-AMP C).Port
COM-RX
Control GainAmplifier Working ModeSlot 16 (OPT-AMP C).Port
LINE-TX
0.0 dBAmplifier TiltSlot 16 (OPT-AMP C).Port
LINE-TX
1.0 dBmPowerSlot 16 (OPT-AMP C).Port
LINE-TX
Step 7 Click Apply.
Step 8 Click the Provisioning > WDM-ANS > Port Status tabs.
Step 9 Click Launch ANS.
Step 10 In the Apply Launch ANS dialog box, click Yes.
Step 11 In the Launch ANS confirmation dialog box, click OK.
Step 12 In node view (single-shelf mode) or multishelf view (multishelf mode), click the Provisioning > WDM-ANS
> Provisioning tabs.
Step 13 Verify the following in the Results column:
• Success - Changed —The parameter has been successfully changed with the ports in IS.
Step 14 Verify that the Set By column displays t he value “ANS” or “APC” as the application that sets the
ANS parameter.
Step 15 Return to your originating procedure (NTP).
DLP-G694 Configuring the PSM Card
This tasks configures the PSM behavior.Purpose
NoneTools/Equipment
DLP-G46 Log into CTCPrerequisite Procedures
As neededRequired/As Needed
Onsite or remoteOnsite/Remote
Turning Up a Node
12
Turning Up a Node
DLP-G694 Configuring the PSM Card