EasyManua.ls Logo

Cisco ONS 15454 - DLP-G376 Installing Fiber-Optic Cables on the Y-Cable Modules in the Y-Cable Module Tray

Cisco ONS 15454
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
When you close the fiber-storage tray, the cables must not be pinched, and the cable bend radius
must be equal to or greater than the minimum radius that is recommended in your site specifications.
As you route each cable through the fiber-storage tray, make sure that adequate cable slack remains.
Caution
Step 3 Install a fiber-optic cable between the client device and the Y-cable module where you just installed a fiber-optic
cable to the TXP, MXP, GE_XP, 10GE_XP, GE_XPE, or 10GE_XPE card.
Step 4 Repeat Steps 1 through 3 for each Y-cable module you need to use for Y-cable protection.
Step 5 Return to your originating procedure (NTP).
DLP-G376 Installing Fiber-Optic Cables on the Y-Cable Modules in the Y-Cable
Module Tray
This task installs fiber-optic cables from the TXP,
MXP, GE_XP, 10GE_XP, GE_XPE, or 10GE_XPE
cards to the Y-cable modules installed in the Y-cable
module tray, and from the Y-cable modules to the
client devices.
Purpose
Fiber-optic cables (4-meter [13.12-foot]), single-mode
or multimode as appropriate
Cisco Transport Planner Internal Connections Report
Tools/Equipment
“DLP-G32 Install the Y-Cable Protection Modules in
the FlexLayer Shelf” in the Cisco ONS 15454
Hardware Installation Guide
NTP-G179 Installing the Transponder and Muxponder
Cards
Prerequisite Procedures
As neededRequired/As Needed
OnsiteOnsite/Remote
NoneSecurity Level
Procedure
Step 1 Open the drawer of the tray by pushing inward on the latches located at the left and right front of the tray.
Step 2 On each Y-cable module you will connect, use the tab to slide the module up so that it is fully extended and
easily accessible in the tray.
Step 3 Referring to the Cisco Transport Planner Internal Connections Report, install a 4-meter (13.12-foot) fiber-optic
cable (single-mode or multimode, as appropriate) between a TXP, MXP, GE_XP, 10GE_XP, GE_XPE, or
10GE_XPE card and the Y-cable module installed farthest to the left. Proceed according to the port label
affixed to the front of the tray to identify the ports on each installed module.
Turning Up a Node
58
Turning Up a Node
DLP-G376 Installing Fiber-Optic Cables on the Y-Cable Modules in the Y-Cable Module Tray

Table of Contents