EasyManua.ls Logo

Cisco ONS 15454 - NTP-G34 Installing Fiber-Optic Cables on DWDM Cards and DCUs

Cisco ONS 15454
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Procedure
Step 1 Open the card ejectors.
Step 2 Slide the card along the guide rails into the correct slot.
Step 3 Close the ejectors.
Step 4 Repeat for any remaining unused card slots.
Stop. You have completed this procedure.
NTP-G34 Installing Fiber-Optic Cables on DWDM Cards and
DCUs
This procedure attaches fiber-optic cables on the
DWDM cards and DCUs.
Purpose
Fiber-optic cables
Cisco Transport Planner Internal Connections Report
Tools/Equipment
NTP-G30 Installing the DWDM cards
NTP-G31 Installing the DWDM Dispersion
Compensating Units
NTP-G139 Verifying Cisco Transport Planner
Reports and Files
Prerequisite Procedures
As neededRequired/As Needed
OnsiteOnsite/Remote
NoneSecurity Level
Class I (CDRH) and Class 1M (IEC) laser products. Statement 1055
Warning
To comply with the Telcordia GR-1089 NEBS, Issue 5 standard, do not use optical fibers with exposed metallic
ferrules. Exposed metallic ferrules may result in ESD damage to the system and can be service affecting.
Caution
For US installations, complies with the US Federal Drug Administration Code of Federal Regulations Title
21, Sections 1040.10 and 1040.11, except for deviations pursuant to Laser Notice No. 50, dated July 26, 2001.
Note
Turning Up a Node
27
Turning Up a Node
NTP-G34 Installing Fiber-Optic Cables on DWDM Cards and DCUs

Table of Contents