Line Rx—Rx direction only
Line Tx & Line Rx—Both Tx and Rx directions
Step 7 In the Recurrence Type area, choose the type of scan to be performed.
The available recurrence types are:
Periodic—To schedule a weekly recurring scan, go to Step 8.
Delta—To schedule a granular recurring scan, go to Step 9.
Step 8 Select the desired values from the Day, Hours, and Min drop-down lists to schedule a periodic scan.
The Day drop-down lists values MON, TUE, WED, THU, FRI, SAT, SUN.
The Hours drop-down lists values from 00 to 23.
The Min drop-down lists values from 00 to 59.
Periodic scan can only be provisioned to run once each week.
Note
Step 9 Select the desired values from the Day, Hours, and Min drop-down lists to schedule a delta scan.
The Day drop-down lists values from 0 to 365.
The Hours drop-down lists values from 00 to 23.
The Min drop-down lists values from 45 to 59.
For Delta scan, the minimum settable interval for Line Tx and Line Rx is 1 hour 30 minutes.
Note
Step 10 Click Apply.
Step 11 Return to your originating procedure (NTP).
DLP-G784 Configuring Threshold Values for OTDR Scan
(Cisco ONS 15454 M6, NCS 2015, ) This task
configures the threshold values for OTDR scan on
TNCS-O and TNCS-2O cards.
Purpose
TNCS-O or TNCS-2O cardTools/Equipment
DLP-G46 Log into CTC
DLP-G788 Configuring Operating Mode for the
TNC, TNCE, TNCS, and TNCS-O Cards task
in the Cisco ONS 15454 DWDM Control Card
and Node Configuration Guide, Release 10.x.x