Procedure
Step 1 Open the patch panel tray:
• 40-channel patch panel tray—On the front of the patch panel tray, push the tabs on the left and right
sides inward to release the lock on the tray. Pull the patch panel tray away from the shelf until it is fully
opened.
• Mesh patch panel tray—On the front of the patch panel tray, push the tabs on the left and right sides
inward to open the front door. Raise the plunger located to the right of the TEST ACCESS TX port and
pull the tray away from the rack.
Step 2 Complete the DLP-G430 Installing Fiber-Optic Cables from the 40-MUX-C and 40-DMX-C Cards to the
40-Channel Patch Panel Tray, on page 51.
Step 3 Complete the DLP-G431 Installing Fiber-Optic Cables from the 40-WXC-C, or 40-SMR-C Cards to a mesh
Patch Panel Tray.
Step 4 Close the patch panel tray:
• 40-channel patch panel tray: Push the tray back toward the rack until it locks into place.
• Mesh patch panel tray: Raise the plunger located on the right of the TEST ACCESS Tx port and push
the tray until the plunger locks into the closed position.
When you close the patch panel tray, the cables must not be pinched, and the cable bend radius
must be equal to or greater than the minimum radius that is recommended in your site specifications.
As you route each cable through the tray, make sure that adequate cable slack remains.
Caution
Stop. You have completed this procedure.
DLP-G430 Installing Fiber-Optic Cables from the 40-MUX-C and 40-DMX-C
Cards to the 40-Channel Patch Panel Tray
This task describes how to route fiber-optic cables
from 40-MUX-C and 40-DMX-C cards in mesh node
to the 40-channel (80-port) patch panel tray
(15454-PP-80). In a mesh node, one 40-channel patch
panel tray is required for each direction. The Side A
40-MUX-C and 40-DMX-C cards will connect to the
Side A 40-channel patch panel. The Side B
40-MUX-C and 40-DMX-C cards will connect to the
Side B 40-channel patch panel, and so forth, up to a
maximum of an eight-degree mesh node (Sides A
through H).
Purpose
Turning Up a Node
51
Turning Up a Node
DLP-G430 Installing Fiber-Optic Cables from the 40-MUX-C and 40-DMX-C Cards to the 40-Channel Patch Panel Tray