Step 8 Route the fiber cable on the card faceplate through the fiber clip on the faceplate, if provided. (Fiber clips are
factory-attached to the faceplates of 32MUX-O, 32DMX, 32DMX-O, OSCM, OSC-CSM, OPT-PRE, OPT-BST,
OPT-BST-E, OPT-BST-L, OPT-AMP-L, OPT-AMP-17-C, OPT-AMP-C, OPT-RAMP-C, OPT-RAMP-CE,
OPT-EDFA-17, OPT-EDFA-24, and OPT-EDFA-35 cards.)
Step 9 Route the fiber cable through the cable-routing channel and cutout on the appropriate side of the shelf assembly,
as necessary.
Step 10 As needed, route slack fiber-optic cable around the round cable retainers in the fiber-storage tray.
Figure 2: Fiber-Storage Tray
When you close the fiber-storage tray, the cables must not be pinched, and the cable bend radius
must be equal to or greater than the minimum radius that is recommended in your site specifications.
As you route each cable through the fiber-storage tray, make sure that adequate cable slack remains.
Caution
Step 11 Route the fiber cable out either side of the fiber-storage tray as necessary.
Step 12 Plug the other end of the cable into the Destination position.
Cards display an SF LED after the OSC terminations are created if transmit and receive fibers are
not connected correctly. For example, an RX port is connected to another RX port or a TX port is
connected to another TX port.
Note
Step 13 Repeat Steps 4 through 12 until you have connected the intra-shelf fibers according to the Cisco Transport
Planner Internal Connections report.
Step 14 To close the fiber-storage tray, push the tray back toward the rack until it locks into place.
Stop. You have completed this procedure.
DLP-G349 Using the Cisco Transport Planner Internal Connections Report
This task describes how to use the Cisco Transport
Planner Internal Connections report to install cables
on the DWDM cards.
Purpose
NoneTools/Equipment
Turning Up a Node
29
Turning Up a Node
DLP-G349 Using the Cisco Transport Planner Internal Connections Report

Table of Contents

Other manuals for Cisco ONS 15454

Related product manuals