What to do next
Removing the Left CEM Module, on page 123
Removing the Left CEM Module
The server has multiple CEM Modules which occupy the right and left sides of the server. Right and left are
in relation to the rear of the server.
The CEM on the left side of the server is secured by four (4) M3x L6mm Phillips screws, two screws on the
server's sheetmetal side wall and two on the front faceplate of the server.
Gather a #2 Phillips screwdriver before starting this procedure.
Before you begin
For Recyclers Only! This procedure is not a standard field-service option. This procedure is for recyclers
who will be reclaiming the electronics for proper disposal to comply with local eco design and e-waste
regulations.
Warning
Procedure
Step 1 Using the screwdriver, remove all four M3x L6mm screws.
Step 2 Grasping the CEM Module, lift it straight up out of the server.
Cisco UCS C885A M8 Server Installation and Service Guide
123
Recycling Server Components
Removing the Left CEM Module