Recycling SAS or NVMe SSDs
The server contains data storage in SAS or NVMe SSDs in the front-mounted drives.
Use this procedure to remove the SSDs for recycling.
Before you begin
This procedure requires access to the front of the server. If you haven't already removed the front bezel, do
so now.
For this procedure, gather a #2 Phillips screwdriver.
Procedure
Step 1 With the front bezel removed, remove the SAS/NVMe SSD carrier from the server.
a) Push the drive carrier button to disengage the carrier assembly from the server chassis.
b) Grasp the drive carrier bezel and pull it outward.
c) Gently pull the drive carrier assembly out of the server.
Figure 145: Removing an SSD
Step 2 Remove the SAS/NVMe drive from the drive carrier assembly.
a) Using a Phillips screwdriver, remove the four screws.
b) Remove the SAS/NVMe drive from the carrier.