Eclipse | Upgrade Guide
Page 165
Where xxxxxx represents a product number.
Table 14-2: Locating Panel *.fwp files
Tip: For help with selecting the other procedures you require for upgrading to Eclipse HX
v9.1, see the quick reference procedures tables in 2 Selecting Upgrade Procedures.
14.1.2 V-Series upgrades
You cannot upgrade any other panels during a V-Series panel upgrade.
The size of the V-Series firmware means that it cannot be stored in the flash memory of
the matrix during the upload, and has to be retained in the upload buffer. If an attempt
is made to upgrade another panel while the V-Series panel is being upgraded, the V-
Series firmware upload will be overwritten.
Clear-Com also recommends that you do not download any configurations during the V-
Series panel upgrade. An Apply Changes download from EHX will break a V-Series
panel upgrade (the download partially resets the configuration for each panel and this
makes the rack "forget" that it is upgrading the panel).
14.2 Upgrading panel application code manually
The application code for most panels can be upgraded manually either by re-
programming the PROM or by directly connecting the panel to a PC. Before attempting
any upgrade, ensure that anti-static precautions are taken, as Eclipse HX devices are
sensitive to static discharges.
Observe all electrical shock hazard warning and precautions for
handling electrostatic sensitive devices
Tip: For help with selecting the other procedures you require for upgrading to Eclipse HX
v9.1 see the quick reference procedures tables in 2 Selecting Upgrade Procedures.
Cabling for i-Station upgrades
14.2.1 Manually upgrading i-Station & E-Station panel
application code
Before you manually upgrade the application code for i-Station & E-Station panels,
ensure that you have the following equipment:
An i-Station serial interconnect lead.
RS232/RS422 adaptor (see Figure 14-1: Example converter cable).