Troubleshooting
Apex Tool Group
P2544PM | 2022-12 | REV H
59
7
EN
Error message
Description
MDSI
Safety torque exceeded
NOK
Rundown is not ok
OFF
Torque encoder offset error
OK
Rundown is ok
RC
Rundown terminated by interruption of the start signal
SS>
Max. number of cycles for stick-slip exceeded
SST
Too many stick-slip edges
TMAX
Canceled by exceeding the max. time
TQ<
Torque too low
TQ>
Torque too high
TTT<
Time that may lapse after threshold torque maximum. If this time is ex-
ceeded, there is a shut-off with this error message.
TTT>
Time that must pass in the Shut-Off Value after threshold torque minimum is
reached. If the time is less, this error message is output.
Error messages of the gyroscope
Error message
Possible cause
Measure
GAE
Invalid angle value re-
turned from gyroscope.
Contact a Sales & Service Center, see reverse.
GAEX
Tool rotated more than
±180°.
Don‘t rotate tool not more than ±180°.
GARE
Tool moved too fast, angle
rate too high.
Move the tool slower while tightening.
GCOM
Internal communication er-
ror
Check gyroscope contact. If error occurs again
contact Sales & Service Center, see reverse.
GVE
Supply voltage too high or
too low
Contact a
Sales & Service Center
, see reverse.
Error messages, software updates and data storage
Error message
Description
Measure
E1
Export script not available.
Try to export the script two to three times.
If the error message continues to occur, perform a
software update.
E2
Error during export.
Insert SD card.
Check SD card for errors.
E3
Error while writing the ar-
chive.
Check SD card for errors.
E10
Software update script not
available.
Try two to three times to perform the software up-
date
If the error message continues to occur, contact a
Sales & Service Center, see reverse
E50
Crash during software up-
date.
E99
Timeout on startup expired.
Insert SD card.
E110
No compatible update
packages found.
Make sure there is the right *.tma file selected.
E200
Several *.tma files availa-
ble.
Select only one *.tma file.
E210
No compatible update
packages found.
Make sure there is the right *.tma file selected.