TABLE 3
PHYSICALDATAAND SPECIFICATIONS DOWNFLOW/HORIZONTAL- MODELS
U.S.and Canadian Models
MODELNUMBERS
04EMAE• 06EMAE• 07EMAE•
07EYBG* O!IEZAJ* 10EZAJ* 12ERAJ*
(·)GTA·SERIES
04NMAE*
06NMAE*
07NMAE*
07NYBG•
09NZAJ*
10NZAJ•
12NRAJ*
INPUT·BTUIHR[kW]:J)
45,000
[13.19]
60,000
[17.58]
75,000
[21.98]
75,000
[21.98]
90,000
[26.38]
105,000
[30.77]
120,000
[35.17]
HEATINGCAPACITY
BTU/HR(kWJ
HIGHALTITUDEINPUT
[kW]@
HIGHALTITUDEOUTPUT
CAPACITY[kW]
(1)
BLOWER{D x W)
[mm]
MOTORH.P. [W]
SPEEDS·TYPE
MOTORFULLLOADAMPS
HEATINGSPEED
COOLINGSPEED
HEATEXT.STATICPRESSURE
{IN.W.C.) [kPa]
RATEDEXT.STATICPRESSURE
(IN. W.C
J[kPa]
HEATING .2"C.F.M.@
W.C.E.S.P.[Us]
COOLING @ .5' C.F.M.
W.C.E.SP[Us]
TEMPERATURERISE
RANGE°F [°CJ
STANDARD [mm]FILTER
APPROX.SHIPPINGWEIGHT
(LBS.) [kg]
AFUE@
CALIFORNIASEASONAL
EFFICIENCY@
41,000
[12.02]
40,500
[11.87]
37,000
[10.84]
11x7
[279
X 178]
112[373]
4-PSC
6.8
MED-LO
HIGH
10 [.025]
.50 [.124]
890 {420]
1220 [576]
3Q..60
[16.7-33.3]
(2) 12"
X 20"
[305 x508]
111 [50.3]
92.7%
84.9%
56,000
[16.41]
54.000
[15.83]
50,400
[14.17]
11 x7
[279x 178]
112 (373]
4-PSC
6.8
MED·LO
HIGH
.12 [.029]
50 (.124]
885 [418]
11801557)
40·70
[22.2·38.9]
(2) 12·x20·
[305x 508]
117[53.1]
92.4%
86.8%
69,000
[20.22]
67,500
[19.78]
63,000
[18.46]
11x7
[279x 178]
112 [373]
4·PSC
6.8
MED-HI
HIGH
12 [.029]
.50(.124]
1060 [500]
1150 (543]
45-75
[25·41.7]
(2) 12"
X 20"
[305 x508]
123 [55.8]
92.5%
86.4%
69,000
[20.22]
67,500
[19.78]
63,000
[18.46]
12
X 7
[305
X 178j
3/4 [559]
4-PSC
9.5
MED-LO
HIGH
.12 [.029]
.50 [.124]
1375 [649]
1625 [767]
35·65
[19.4-36.1]
(2) 12"
X 20'
[305 x508]
123 [55.8]
92.3%
85.7%
84,000
(24.62]
81,000
(23.74]
75,000
[21.98]
12x11
[305x 279]
3/4 [559]
4·PSC
9.5
MED-LO
HIGH
.15 [.037]
.50 [.124]
1400 [661]
1850 [873]
45-75
{25-41.7]
(2) 12'
X20'
[305 x508]
148 (67.1]
92.4%
86.7%
97,000
[28.43]
94,500
[27.70]
87,500
[25.64]
12
X 11
[305
X279]
3/4 [559]
4-PSC
9.5
MED·LO
HIGH
.20 [.049]
.50 [.124]
1425 [673]
1820 [8591
50·80
[27.8-44.4]
(2) 12'
X 20"
[305
X508]
152 [68.9]
92.0%
870%
112,000
[32.82]
108,000
[31.65]
100,500
[29.45]
11 x10
[279
X 254)
314 [559]
4-PSC
9.5
MED-LO
HIGH
.20 [.049]
.50(.124]
1565 [739]
2040 [963]
50·80
[27.8-44.4]
(2) 14"
X20'
(355
X 508]
160 [72.6]
92.1%
87.4%
,.,
NOTES:All models are 115V, 60HZ, 10. Gas connection size for all models isW [13 mm] N.P.T.
Designates Models."S" for U.S, "B" for Canadian
:D SeeConversion Form No. 92-21519-44 or 92-21519-42 for high altitude Kit Index (U.S.) (Canadian) de rate.
® Canadianmodelsonly.
@ In accordance test pro<:edures. with D.O.E.
10