INDEXOF FIGURES
Page Number
107 Heat Assisted Limit Control ........................................................................................91
108 OverTemperatureSwitch .......................................................................................... 91 •
128 UTEC No. 1012-920 and 1028-927, -928 Control Board Twinning Connection,
129 UTEC No. 1012-920 and 1028-927, -928 Control Board Twinning Connection,
132 Johnson Controls G961DAJ-2401, -2402 Control Board Twinning Connection,
133 Johnson Controls G961 DAJ-2401, -2402 Control Board Twinning Connection,
135 RXPF-F01 Fossil Fuel Kit Wiring Diagram with Ranco DDL Demand Defrost ......... 111 •
109 Transformer................................................................................................................92
110 24 Volt Transformer Connections on Control Board ................................................. 93
111 IFC 6-Pin Plug ............................................................................................................93
112 Induced Draft Blower ........................... ........................................................... .......... 93
113 Integrated Furnace Control........................................................................................94
114 Induced Draft Blower in Unit .. .. .... .. .. . .. .. .. .. .. ................ ... .. .... .. ... . .. .. . ... .. ... .... .. . .. .. ........ 94
115 IFC 9-Pin Plug............................................................................................................ 94
116 Norton Igniter ..............................................................................................................95
117 IFC 6-Pln Plug............................................................................................................ 95
118 OSI Igniter ..................................................................................................................96
119 DSI Igniter Connection...............................................................................................96
120 Flame Sensor............................................................................................................. 97
121 Microamp Meter Reading...........................................................................................97
122 Flue Gas Sampling .... .. ........... ......... ....... ............ .......... .... .......... .................... ........... 99
123 Flue Gas Temperature Measurement .......................................................................99
124 (-)GRA Condensing Gas Furnace Wiring Diagram with Direct Spark Ignition .......... 100
125 (-)GTA Condensing Gas Furnace Wiring Diagram with Direct Spark Ignition .......... 101
126 (-)GRJ Condensing Gas Furnace Wiring Diagram with Hot Surface Ignition ........... 102
127 (-)GTJ Condensing Gas Furnace Wiring Diagram with Hot Surface Ignition ........... 103
Single Stage .........................................................................................................104
Two Stage ............................................................................................................105
130 Honeywell No. S9201E2001 Control Board Twinning Connection, Single Stage .... 106
131 Honeywell No. S9201E2001 Control Board Twinning Connection, Two Stage ....... 107
Single Stage .........................................................................................................108
Two Stage ............................................................................................................109
134 RXPF-F01 Fossil Fuel Kit Wiring Diagram with Time-Temperature Defrost ............110
136 RXPF-F02 Fossil Fuel Kit Wiring Diagram with Time-Temperature Defrost ............ 112
137 RXPF-F02 Fossil Fuel Kit Wiring Diagram with Ranco DDL Demand Defrost... ...... 113
INDEXOF TABLES
1 Physical Data and Specifications - Upflow - (-)GRA Series ....................................
8
2 Physical Data and Specifications - Upflow (-)GRJ Series ..................................... 9
3
Physical Data and Specifications -Downflow/Horizontal - (-)GTA Series .............. . 10
4 Physical Data and Specifications - Downflow/Horizontal- (-)GT J Series .............. . 11
5
Air Flow Performance-(-)GRA and (-)GTA Models .................................................
12
6
Air Flow Performance -(-)GRJ and (-)GTJ Models ..................................................
13
.
8
Combustible Floor Base ............................................................................................. 19
20
LP Kits .......................................................................................................................
56
7 LP Kits ....................................................................................................................... 18
9
Return Air Cabinets ....................................................................................................
19
10
Filter Racks - Upflow .................................................................................................. 20
11
Filter Racks - Downflow ............................................................................................. 20
12
Unconfined Space Dimensions ..................................................................................
30
13
Indoor Air Opening Dimensions ................................................................................. 30
14 Vertical Outdoor
AirOpening Dimensions ................................................................. 31
15
Horizontal Outdoor Air Opening Dimensions ............................................................
31
16
Vertical or Horizontal Outdoor
AirOpening Dimensions ........................................... 31
17 Non-Direct Vent Applications - Combustion Air from Indoors ..................................
33
18
Direct Vent Applications - Combustion Air from Outdoors .......................................
43
19
Gas Pipe Capacity Table ...........................................................................................
53
.
21
Orifice Sizes ..............................................................................................................56.
22
Low Voltage Wiring ....................................................................................................
57
23
High Altitude Kits ........................................................................................................
63
24
Filter Sizes ..................................................................................................................
70
•
25
Negative Pressure Switches ..................................................................................... .
88
26
Main Limit Setting Temperatures .............................................................................. .
90
27
Blower Wheel Dimensions ........................................................................................ . 93
28
Meter Time ................................................................................................................
95
.
124