I
I
I
I
I
I
I
I
,,
MAIN BURNER I
NO
SYSTEM WILL ATTEMPT TO LIGHT 4 TIMES. VOLTAGE IS PRESENT AT THE
LIGHTS
I
-
VALVE FOR ONLY 8 SECONDS DURING EACH TRIAL FOR IGNITION (SYSTEM WILL
YES
GO INTO A 1-HOUR LOCKOUT AFTER 4 TRIES). THE BLOWER AND INDUCED
DRAFT BLOWER WILL RUN 180 SEC. IF THE SECOND IGNITION TRIAL FAILS TO
SENSE FLAME.
CHECK FOR 24 VAC ACROSS THE VALVE
AND VALVE TERMINALS ON THE IFC
CHECK IGNITER POSITION.
I
NO
CHECK FOR GAS FLOW TO AND FROM VALVE.
'f
'f
REPLACE VALVE IF NO I
!
REPLACE IFC IF
FLOW THAU VALVE
WIRING TO VALVE IS OK
'
MAIN BURNER
I
NO
NOTE: IF IFC GOES INTO LOCKOUT WAIT 30 SECONDS THEN
REMAINS POWERED
I
-
RESET SYSTEM
AND LIT
CHECK POLARITY OF 115 VAC SUPPLY
YES
CHECK CONTINUITY OF GROUND WIRE
CHECK INSULATION ON IGNITER
CHECK FLAME SENSE CURRENT (YELLOW LED)
LED IS ON IF FLAME CURRENT IS GOOD,
IT FLASHES IF CURRENT
IS MARGINAL.
• TURN POWER OFF TO UNIT
CLEAN
FLAME SENSOR WITH STEEL WOOL IF LEO FLASHES
RESTORE POWER TO UNIT
,,
IF CHECKS ARE OK, REPLACE IFC
INDOOR BLOWER MOTOR
I
NO
CHECK FOR 115 VAC ACROSS BLOWER
NO
REPLACE IFC IF
STARTS 20 SECONDS
-
MOTOR ANO BLOWER MOTOR TERMINALS WIRING TO BLOWER
AFTER
MAIN BURNER LIGHTS
I
(HEAT AND NEUTRAL) ON IFC MOTOR IS OK
YES
+YES
'
REPLACE BLOWER MOTOR I
SYSTEM RUNS
I
NO
NOTE: IF IFC GOES INTO LOCKOUT WAIT 30 SECONDS THEN
UNTIL CALL FOR
-
I
-
RESET SYSTEM
HEAT ENDS
YES
CHECK CONTINUITY OF GROUND WIRE. NOTE: IF GROUND IS
POOR OR ERRATIC, SHUTDOWN MAY OCCUR OCCASIONALLY EVEN
THOUGH OPERATION IS NORMAL AT THE TIME OF CHECKOUT.
CHECK FLAME SENSE CURRENT
• CHECK FOR EXCESSIVE HEAT AT IGNITER BASE.
• TURN POWER OFF TO UNIT.
• CLEAN FLAME SENSOR WITH STEEL WOOL.
RESTORE POWER TO UNIT.
IF CHECKS ARE OK, REPLACE IFC
I
TURN THERMOSTAT TO OFF
NO
CHECK FOR PROPER THERMOSTAT OPERATION.
VALVE SHUTS OFF
-
I
-
REMOVE VALVE LEAD AT IFC
FLAME GOES OUT
IF VALVE CLOSED, RECHECK THERMOSTAT ANO
YES
WIRING. IF NOT, REPLACE VALVE .
DRAFT MOTOR STOPS AFTER 5 SEC.
I NO
CHECK FOR OPEN LIMIT.
I
- IREPLACE IFC
-tYES
INDOOR BLOWER MOTOR
I
NO
CHECK FOR OPEN LIMIT.
I
STOPS AFTER
-
I
-
REPLACE IFC
90/120/160/180 SECONDS
YES
TROUBLESHOOTING ENDS
I
REPEAT PROCEDURE UNTIL TROUBLEFREE
OPERATION IS OBTAINED.
92-22744-18-01
NOTE:
STATIC DISCHARGE CAN DAMAGE INTEGRATED FURNACE CONTROL (IFC)
"OK" LED BLINKS TO INDICATE EXTERNAL FAULTS:
(1) BLINK FOLLOWED BY A 2 SEC. PAUSE-1 HOUR LOCKOUT
(2) BLINKS FOLLOWED BY A 2
sec.PAUSE - PRESSURE SWITCH IS OPEN
(3) BLINKS FOLLOWED BY A 2 SEC. PAUSE- LIMIT SWITCH IS OPEN
(4} BLINKS FOLLOWED BY A 2 SEC. PAUSE- PRESSURE SWITCH CLOSED
(5) TWINNING FAULT
87