Maintenance Manual SP 40
Rev. 005
40
Chapter 2
Removals
2.15 Selector Cam
DANGER : To prevent serious personal injury from electrical shock always turn the printer off and unplug
the power cable before to remove the selector cam.
Selector cam is item 28 of figure 2.18
To Remove:
1) Remove the top and the main cover assy (see chapter 2.2).
2) Remove the aligner, the drive aligner assy and the spring bar following until point 7 the instructions of
the chapter 2.14.
3) Remove the four screws (item 33 of figure 2.18) fixing the plastic support of the front roller to the front
bed.
4) Remove all the group of the front roller assy.
5) Remove the circlip (item 29 of figure 2.18).
6) Remove the selector cam.
To Install:
To install, follow the removal step in reverse order.
REMARK:
For a correct reassembly operations see the selector cam adjustment instructions reported in the chapter 2.14
or in the chapter 8.
The cam must be lubricate with Molykote PG30L grease as indicated in chapter 4.4.