Received Signal Strength (RSSI) for Radio Zones 1-60
P570E 1-60E RSSI for Radio Zones 1-64 Page 32
Programming Output PA Options
P571E Output #1 Local PA settings -Default = 0 P571E-P578E OPTIONS Page 34
P572E Output #2 Local PA settings -Default = 0 1 = Enable PA O/P On msg Page 34
P573E Output #3 Local PA settings -Default = 0 2 = Use Canned On msg Page 34
P574E Output #4 Local PA settings -Default = 0 3 = Repeat On msg Page 34
P575E Output #5 Local PA settings -Default = 0 4 = Spare Page 34
P576E Output #6 Local PA settings -Default = 0 5 = Enable PA O/P Off msg Page 34
P577E Output #7 Local PA settings -Default = 0 6 = Use Canned Off msg Page 34
P578E Output #8 Local PA settings -Default = 0 7 = Repeat Off msg Page 34
8 = Spare
Received Signal Strength (RSSI) for Radio Pendants 21-100
P580E 21-100E RSSI for Radio Pendants 21-100 Page 32
Programming Output On/Off Time Zone
P581E Output #1 Automatic on / off time zones - Default 0 (never) Page 35
P582E Output #2 Automatic on / off time zones - Default 0 (never) Page 35
P583E Output #3 Automatic on / off time zones - Default 0 (never) Page 35
P584E Output #4 Automatic on / off time zones - Default 0 (never) Page 35
P585E Output #5 Automatic on / off time zones - Default 0 (never) Page 35
P586E Output #6 Automatic on / off time zones - Default 0 (never) Page 35
P587E Output #7 Automatic on / off time zones - Default 0 (never) Page 35
P588E Output #8 Automatic on / off time zones - Default 0 (never) Page 35
Programming Output Inhibit Time Zones
P591E Output #1 Enable time zones - Default 0 (always) Page 35
P592E Output #2 Enable time zones - Default 0 (always) Page 35
P593E Output #3 Enable time zones - Default 0 (always) Page 35
P594E Output #4 Enable time zones - Default 0 (always) Page 35
P595E Output #5 Enable time zones - Default 0 (always) Page 35
P596E Output #6 Enable time zones - Default 0 (always) Page 35
P597E Output #7 Enable time zones - Default 0 (always) Page 35
P598E Output #8 Enable time zones - Default 0 (always) Page 35
Miscellaneous System Options
P601E Options - Default 3,5,7,8 1 = Ignore Mains fail Page 35
2 = Ignore Zone Tampers during exit delay
3 = Installer code direct access
4 = Installer lockout
5 = System Tamper EOL or Short circuit loop
6 = Zones 61-64 use 2k2 EOL of short circuit loop
7 = Key-switch # 1 Momentary or latch
8 = Key-switch # 2 Momentary or latch
P602E Hardwired Zone Options -Default = 3 1 = Zone Doubling on input 61 (Zone 63 enabled) Page 36
2 = Zone Doubling on input 62 (Zone 64 enabled)
3 = RSSI Scale. On = Freelink RSSI, Off = AAP Ash RSSI
4 = No Output data to keypad buss (Off = No O/P data on buss)
Programming Duress Digit
P603E Duress Digit (Value can be 1-9, 0 = disabled) default 0 Page 17
Hardwired Zones 61-64 Response Time Settings
P604E Zone response settings default = 6 (value 1-31E) Page 23
** Upload/Download Security Code **
P605E XXXXXXXX. Up to 8 digit security code -Default = 0 Page 54
**Keypad Listen-in Options**
P606E Keypad Listen-in Options P212E Options (Default = 1-7 On) Page 53
1 = Enabled During Dialling in Disarm State only