Page 73
P748E Keypad Fire Alarm (button 4 & 6) Contact ID Code (Default=110) Page 53
**Keypad Medical Alarm Contact ID Reporting Code**
P749E Keypad Medical Alarm (button 7 & 9) Contact ID Code (Default=100) Page 53
** System reporting Options **
P750E System options (Default = 2,6,7) Page 48
1 = Enable communicator 5 = Reverse Style Pulse
2 = Fax defeat 6 = Report 24hr alarms in Voice/Domestic
3 = Disable line monitoring 7 = Auto-Detect Modem Format
4 =DTMF or Pulse 8 = Force Bell103/V21
** Reporting Scenarios **
P752E Reporting Scenario #1 options (Default = 1,7) Page 48
P753E Reporting Scenario #2 options (Default = 0) Page 48
P754E Reporting Scenario #3 options (Default = 0) Page 48
P755E Reporting Scenario #4 options (Default = 0) Page 48
** Maximum Dialling Attempts per Scenario **
P756E Max Dial Attempts for Scenario Number 1-Value 1-99 (Default=20) Page 49
P757E Max Dial Attempts for Scenario Number 2-Value 1-99 (Default=20) Page 49
P758E Max Dial Attempts for Scenario Number 3-Value 1-99 (Default=20) Page 49
P759E Max Dial Attempts for Scenario Number 4-Value 1-99 (Default=20) Page 49
** Auto Answer Ring Count **
P760E Auto-answer ring count - default = 25 Page 54
Output Reset Times
P761E Output #1 reset time - Default 600 sec Reset time values Page 38
P762E Output #2 reset time - Default 600 sec 0 = latching Page 38
P763E Output #3 reset time - Default 600 sec 1-999 = 1 to 999 seconds Page 38
P764E Output #4 reset time - Default 600 sec Page 38
P765E Output #5 reset time - Default 0 sec Page 38
P766E Output #6 reset time - Default 0 sec Page 38
P767E Output #7 reset time - Default 0 sec Page 38
P768E Output #8 reset time - Default 0 sec Page 38
** Mains Failure Reporting Delay **
P769E Mains Fail Reporting Delay to Dialler (0-999 sec) - Default = 600 Page 39
** Zone Alarm Reporting Delay **
P770E Zone Reporting Delay to Dialler (0-999 sec) - Default = 0 Page 39
Output On Delay Times
P771E Output #1 delay on timer - Default 0 Delay time values Page 39
P772E Output #2 delay on timer - Default 0 0 = no delay Page 39
P773E Output #3 delay on timer - Default 0 1 - 999 = 1 to 999 seconds Page 39
P774E Output #4 delay on timer - Default 0 Page 39
P775E Output #4 delay on timer - Default 0 Page 39
P776E Output #5 delay on timer - Default 0 Page 39
P777E Output #6 delay on timer - Default 0 Page 39
P778E Output #7 delay on timer - Default 0 Page 39
Zone Inactivity Time
P779E Zone Inactivity Timer (0-255 hour) - Default = 120 Hours Page 39
Supervised Radio Time
P780E Supervised Radio Timer (0-255 minutes) - Default = 240 Minutes Page 39
Output Pulse Times
P781E Output #1 pulse time - Default 1 Pulse time values Page 39
P782E Output #2 pulse time - Default 1 1-999 (min of 1) Page 39
P783E Output #3 pulse time - Default 1 1 to 999 in 1/10 secs Page 39
P784E Output #4 pulse time - Default 1 e.g. 1 = 0.1 second Page 39