EasyManua.ls Logo

Crow PowerWave-64 - System Events to Scenario Mapping

Crow PowerWave-64
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 74
P785E Output #5 pulse time - Default 1 10 = 1 second Page 39
P786E Output #6 pulse time - Default 1 Page 39
P787E Output #7 pulse time - Default 1 Page 39
P788E Output #8 pulse time - Default 1 Page 39
** System Events to Scenario Mapping **
P791E Duress Alarm mapped to scenario 1-4 default 1 Page 51
P792E Keypad “Panic” (& buttons 1 & 3) mapped to scenario 1-4 default 1 Page 51
P793E Keypad “Fire” (buttons 4 & 6) mapped to scenario 1-4 default 1 Page 51
P794E Keypad “Medical” (buttons 7 & 9) mapped to scenario 1-4 default 1 Page 51
P795E Battery low mapped to scenario 1-4 default 1 Page 51
P796E Mains fail mapped to scenario 1-4 default 1 Page 51
P797E Phone line restore mapped to scenario 1-4 default 1 Page 51
P798E Radio PIR battery low mapped to scenario 1-4 default 1 Page 51
P799E Radio-key battery low mapped to scenario 1-4 default 1 Page 51
P800E Keypad tamper mapped to scenario 1-4 default 1 Page 51
P801E Cabinet tamper mapped to scenario 1-4 default 1 Page 51
P802E Zone tamper mapped to scenario 1-4 default 1 Page 51
P803E Radio panic mapped to scenario 1-4 default 1 Page 51
P804E Supervised Radio Timeout mapped to scenario 1-4 default 1 Page 51
P805E Zone Inactivity Timeout mapped to scenario 1-4 default 1 Page 51
P806E Test calls mapped to scenario 1-4 default 1 Page 51
Partition “D” Primary Output Options
P811E-P818E OPTIONS
P811E Area “D” primary options for output #1- Default 1 1 = Standard zone activation's Page 23
P812E Area “D” primary options for output #2 - Default 1 & 2 2 = Stay Mode activation's Page 23
P813E Area "D" primary options for output #3 - Default 1 3 = Radio key chirps Page 23
P814E Area "D" primary options for output #4 - Default 1 4 = All zones sealed (ready) Page 23
P815E Area "D" primary options for output #5 - Default 1 5 = 2 sec pulse on arm/disarm Page 23
P816E Area "D" primary options for output #6 - Default 1 6 = Day zone activation's Page 23
P817E Area "D" primary options for output #7 - Default 1 7 = Spare Page 23
P818E Area "D" primary options for output #8 - Default 1 8 = Spare Page 23
Partition “D” Keypad Options
P819E Arm key can disarm during exit - Default 1-8 Page 25
P820E Stay key can disarm during Stay armed state - Default 1-8 Page 25
Partition “D” Secondary Output Options
P821E-P828E OPTIONS
P821E Area "D" secondary options for output #1 - Default 0 1 = Any exclude Page 24
P822E Area "D" secondary options for output #2 - Default 0 2 = Auto exclude warn Page 24
P823E Area "D" secondary options for output #3 - Default 0 3 = Entry beeps Page 24
P824E Area "D" secondary options for output #4 - Default 0 4 = Exit Beeps Page 24
P825E Area "D" secondary options for output #5 - Default 0 5 = Control Page 24
P826E Area "D" secondary options for output #6 - Default 0 6 = Follow Set Arming Page 24
P827E Area "D" secondary options for output #7 - Default 0 7 = Follow Stay Arming Page 24
P828E Area "D" secondary options for output #8 - Default 0 8 = Follow Unset Page 24
Programming Partition “D” Auto Arm/Disarm Time-zones
P829E Time Zones used for Area "D" auto arming /disarming- Default 0 (see P832E) Page 25
Partition “D” Misc Options
P830E Misc partition options 1 - Default 0 1 = Cannot Arm if not sealed Page 25
2 = “Arm” required before code
3 = “Stay” required before code
4 = Code required to arm
5 = Code required to “Bypass” zones
6 = Control disables day zones
7 = Repeat System PA messages
8 = Spare
P831E Misc partition options 2 - Default 3,4,6 1 = Key-switch enabled Page 26
2 = Use 2nd Key-switch
3 = Key-switch ARM's/STAY

Table of Contents