SiEN18-622 Instruction
System Configuration 251
FILTERS
1. Open the front grille.
2. Pull out the air filters.
Push upwards the tab at the center of each
air filter, then pull it down.
3. Take off the air purifying filter, photocatalytic
deodorizing filter.
Hold the recessed parts of the frame and
unhook the four claws.
4. Clean or replace each filter.
See below.
5. Set the air filter, air purifying filter and
photocatalytic deodorizing filter as they were
and close the front grille.
Insert claws of the filters into slots of the front
grille.
Push the grille at the 5 points
Air Filter
1. Wash the air filters with water or clean them
with vacuum cleaner.
If the dust does not come off easily, wash
them with neutral detergent thinned with
lukewarm water, then dry them up in the
shade.
It is recommended to clean the air filters
every two weeks.
Air Purifying Filter (green)
(Replace approximately once every 3 months.)
1. Detach the filter element and attach a new
one.
Insert with the green side up.
It is recommended to replace the air
purifying filter every three months.
Photocatalytic Deodorizing Filter (gray)
[Maintenance]
1. Dry the photocatalytic deodorizing filter in the sun.
After removing the dust with a vacuum cleaner, place the filter in the sun for approximately 6
hours. By drying the photocatalytic deodorizing filter in the sun, its deodorizing and antibacterial
capabilities are regenerated.
Because the filter material is paper, it can not be cleaned with water.
It is recommended dry the filter once every 6 months.
[Replacement]
1. Detach the filter element and attach a new one.
Air purifying filter