Danfoss VLT AQUA Drive FC 202 Programming Guide

Danfoss VLT AQUA Drive FC 202
294 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
Q3-1 General settings
Q3-10 Clock Settings Q3-11 Display Settings Q3-12 Analog Output Q3-13 Relays
Parameter 0-70 Date and Time Parameter 0-20 Display Line 1.1
Small
Parameter 6-50 Terminal 42 Output Relay
1Parameter 5-40 Function
Relay
Parameter 0-71 Date Format Parameter 0-21 Display Line 1.2
Small
Parameter 6-51 Terminal 42 Output
Min Scale
Relay
2Parameter 5-40 Function
Relay
Parameter 0-72 Time Format Parameter 0-22 Display Line 1.3
Small
Parameter 6-52 Terminal 42 Output
Max Scale
Option relay
7Parameter 5-40 Function
Relay
Parameter 0-74 DST/Summertime Parameter 0-23 Display Line 2
Large
Option relay
8Parameter 5-40 Function
Relay
Parameter 0-76 DST/Summertime
Start
Parameter 0-24 Display Line 3
Large
Option relay
9Parameter 5-40 Function
Relay
Parameter 0-77 DST/Summertime
End
Parameter 0-37 Display Text 1
Parameter 0-38 Display Text 2
Parameter 0-39 Display Text 3
Table 2.2 Q3-1 General Settings
Q3-2 Open-loop settings
Q3-20 Digital reference Q3-21 Analog reference
Parameter 3-02 Minimum Reference Parameter 3-02 Minimum Reference
Parameter 3-03 Maximum Reference Parameter 3-03 Maximum Reference
Parameter 3-10 Preset Reference Parameter 6-10 Terminal 53 Low Voltage
Parameter 5-13 Terminal 29 Digital Input Parameter 6-11 Terminal 53 High Voltage
Parameter 5-14 Terminal 32 Digital Input Parameter 6-14 Terminal 53 Low Ref./Feedb. Value
Parameter 5-15 Terminal 33 Digital Input Parameter 6-15 Terminal 53 High Ref./Feedb. Value
Table 2.3 Q3-2 Open-loop Settings
Q3-3 Closed-loop settings
Q3-30 Feedback settings Q3-31 PID settings
Parameter 1-00 Conguration Mode Parameter 20-81 PID Normal/ Inverse Control
Parameter 20-12 Reference/Feedback Unit Parameter 20-82 PID Start Speed [RPM]
Parameter 3-02 Minimum Reference Parameter 20-21 Setpoint 1
Parameter 3-03 Maximum Reference Parameter 20-93 PID Proportional Gain
Parameter 6-20 Terminal 54 Low Voltage Parameter 20-94 PID Integral Time
Parameter 6-21 Terminal 54 High Voltage
Parameter 6-24 Terminal 54 Low Ref./Feedb. Value
Parameter 6-25 Terminal 54 High Ref./Feedb. Value
Parameter 6-00 Live Zero Timeout Time
Parameter 6-01 Live Zero Timeout Function
Table 2.4 Q3-3 Closed-loop Settings
How to Program
VLT
®
AQUA Drive FC 202
20 Danfoss A/S © 05/2018 All rights reserved. MG20OB02
22

Table of Contents

Other manuals for Danfoss VLT AQUA Drive FC 202

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AQUA Drive FC 202 and is the answer not in the manual?

Danfoss VLT AQUA Drive FC 202 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AQUA Drive FC 202
CategoryDC Drives
LanguageEnglish

Related product manuals