TWO-HEAD DIMENSIONING SYSTEM REFERENCE MANUAL
Select the check box to enable. When checked, a Separator text field is
revealed. Enter a separator character in the text field provided. Alibi storage
information is appended after the separator. This is a MAC address, followed
by a 10 digit sequence number, dash, then 14 char date/time.
Format: 00:0e:13:05:00:01nnnnnnnnnn-YYYYMMDDhhmmss
NOTE: Alibi is only available for controller
model DC3000-1200 (OIML) and
dimensioner model DM3610-3200 (OIML).
Select the check box to enable. When checked, Volume Units, Volume
Field Width, and Volume Precision drop-down boxes are revealed.
Select cubic Volume Units from the drop-down list. Selections include in³
(inches cubed), ft³ (feet cubed), cm³ (centimeters cubed), and dm³
(decimeters cubed).
Select a Volume Field Width of 2 to 8 from the drop-down list. This
represents the number of characters available for the field width. If the value
has fewer characters than the field width, it will be padded with zeros on the
left.
Select a Volume Precision of 0 to 3 from the drop-down list. This is the
number of digits appearing after the decimal point.
For example:
If Volume Precision is set at 1 (1 decimal place), Volume
Field Width is set at 5, and the volume is 25.8 cm³, then the
returned value in the host message will be 025.8
If Volume Precision is set at 2 (2 decimal place), Volume
Field Width is set at 8, and the volume is 25.8 cm³, then the
returned value in the host message will be 00025.80
Enter a heart beat message in milliseconds if desired. If no other message is
sent for the time period specified in Heart Beat Time Out, the specified heart
beat message string is sent.
NOTE: A time-out of zero disables the heart beat
message.
Heart Beat
Time Out
(0-30,000 ms)
Enter an interval for heart beat time out in milliseconds. 0 = Disable Heart
Beat Message, 1-30,000 = Delay before sending Heart Beat Message
3. When you have finished making changes, click Update to save or click Reset to
revert to the previously saved values.