Wireless Features
Product Reference Guide
305
STAR Radio Protocol Timeout
This parameter sets the valid wait time before transmission between the
handheld reader and Base Station is considered failed.
When setting this parameter, take into consideration the radio traffic (num-
ber of readers in the same area). The selectable range for this feature is from
02
to 25 seconds.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the number with leading zeroes to yield two digits. For example: 2
= 02, 5 = 05, 25 = 25, etc
3. Go to page 238 and scanScan the ENTER/EXIT PROGRAMMING MODE
barcode to enter Programming Mode.
4. Scan the barcode: SELECT RADIO PROTOCOL TIMEOUT.
5. Scan the appropriate two digits from the keypad in Appendix D, Key-
pad, that represent the duration which was determined in the steps
above. You will hear a two-beep indic
ation after the last character.
If you make a mistake before the last character, scan the CANCEL bar-
code to abort and not save the entry string. You can then start again
at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program-
ming Mode.
This completes the procedure. See Table 44 for some examples of how to
set this feature.
Table 44. STAR Radio Protocol Timeout Examples
STEP ACTION EXAMPLES
1 Desired Setting
2 Seconds 5 Seconds 10 Seconds 25 Seconds
2
Pad with leading
zero(es
)
02 05 10 25
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECTSTAR RADIO PROTOCOL TIMEOUT SETTING
5
Scan Two Characters
From
Appendix D,
Keypad
‘0’ and ‘2’ ‘0’ and ‘5’ ‘1’ and ‘0’ ‘2’ AND ‘5’
6 Scan ENTER/EXIT PROGRAMMING MODE

Table of Contents

Other manuals for Datalogic PowerScan PD9531-AR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan PD9531-AR and is the answer not in the manual?

Datalogic PowerScan PD9531-AR Specifications

General IconGeneral
BrandDatalogic
ModelPowerScan PD9531-AR
CategoryBarcode Reader
LanguageEnglish

Related product manuals