Enter/Exit Programming Mode
46
PowerScan™ PD9531-AR/PBT9501-AR/PM9501-AR
Wedge Quiet Interval
Specifies amount of time to look for keyboard activity before scanner breaks 
keyboard connection in order to transmit data to host. The selectable range 
for this setting is 00 to 990 milliseconds (00-0x63 by 01) in increments of 
ten milliseconds.
 See page 286 in “References” for detailed information and 
examples for setting this feature.
Set Wedge Quiet Interval
To configure this feature, scan the ENTER/EXIT 
PROGRAMMING MODE bar code above, then 
the bar code at left followed by the digits from 
the Alphanumeric characters in 
Appendix D, 
Keypad representing your desired character(s). 
End by scanning the ENTER/EXIT bar code 
aga
in.
Make a mistake? Scan the CANCEL bar code to 
abor
t and not save the entry string. You can 
then start again at the beginning.
CANCEL
DEFAULT
0A = Quiet Interval is 
100 milliseconds