EasyManuals Logo

Datalogic PowerScan PD9531-AR User Manual

Datalogic PowerScan PD9531-AR
362 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #138 background imageLoading...
Page #138 background image
Enter/Exit Programming Mode
128
PowerScan™ PD9531-AR/PBT9501-AR/PM9501-AR
I 2 of 5 Set Length 1
This feature specifies one of the bar code lengths for I 2 of 5 Length Control.
Length 1 is the minimum label length if in Variable Length Mode, or the first
fixed length if in Fixed Length Mode. Th
e length includes the bar code’s
check and data characters. The length can be set from 2 to 50 characters in
increments of two.
Table 8 provides some examples for setting Length 1. See page 289 for
detailed instructions on setting this feature.
Table 8. I 2 of 5 Length 1 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
2 Characters 6 Characters 14 Characters 50 Characters
2
Pad with leading zeroes
to yield two
digits
02 06 14 50
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT I 2 of 5 LENGTH 1 SETTING
5
Scan Two Characters
From
Appendix D,
Keypad
‘0’ and ‘2’ ‘0’ and ‘6’ ‘1’ and ‘4’ ‘5’ AND ‘0’
6 Scan ENTER/EXIT PROGRAMMING MODE
Select I 2 of 5 Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
DEFAULT
06 = Length 1 is 6 Characters

Table of Contents

Other manuals for Datalogic PowerScan PD9531-AR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan PD9531-AR and is the answer not in the manual?

Datalogic PowerScan PD9531-AR Specifications

General IconGeneral
BrandDatalogic
ModelPowerScan PD9531-AR
CategoryBarcode Reader
LanguageEnglish

Related product manuals