Scanning Features
Product Reference Guide
303
Flash Off Time
This feature specifies the OFF time for the indicator LED while in Flash Mode. 
The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 
100 millisecond increments.
Follow these instructions to set this feature.
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 100 (setti
ng is in 100ms increments). Pad 
the result with leading zeroes to yield two digits. For example: 0 = 00, 
5 = 05, 20 = 20, etc.
3. Go to page 79 and scan the ENTER/EXIT PROGRAMMING MODE bar code 
to enter Programming Mode.
4. Scan the bar code: SELECT 
FLASH OFF TIME SETTING.
5. Scan the appropriate two digits from the keypad in Appendix D, Key-
pad, that represent the duration which was determined in the steps 
above. You will hear a two-beep indic
ation after the last character.
If you make a mistake before the last character, scan the CANCEL bar 
code to abort and not save the entry string. You can then start again 
at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Program-
ming Mode.
This completes the procedure. See Table 42 for some examples of how to 
set this feature.
Table 42. Flash Off Time Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
500ms
1,000ms (1 
sec.)
5200ms (5.2 
sec
.)
9,900ms (9.9 sec.)
2
Divide by 100 (and pad 
with leading zeroes to 
yield two digit
s)
05 10 52 99
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT FLASH OFF TIME SETTING
5
Scan Two Characters 
From 
Appendix D, 
Keypad
 ‘0’ and ‘5’ ‘1’ and ‘0’ ‘5’ and ‘2’  ‘9’ and ‘9’
6 Scan ENTER/EXIT PROGRAMMING MODE