Enter/Exit Programming Mode UPC-E
96 QuickScan™ I QM21X1 / QBT21X1
UPC-E Number System Character Transmission
This feature enables/disables transmission of the UPC-E system number char-
acter.
UPC-E Minimum Reads
This feature specifies the minimum number of consecutive times a UPC-E label
must be decoded before it is accepted as good read.
$CEBNS00
UPC-E Number System Character = Do not transmit
$CEBNS01
UPC-E Number System Character = Transmit
DEFAULT
$CEBMR01
UPC-E Minimum Reads = 1
$CEBMR02
UPC-E Minimum Reads = 2
$CEBMR03
UPC-E Minimum Reads = 3
$CEBMR04
UPC-E Minimum Reads = 4
DEFAULT