Enter/Exit Programming Mode MSI
218 QuickScan™ I QM21X1 / QBT21X1
MSI Check Character Transmission
Enables/disables transmission of an MSI check character.
MSI Length Control
This feature specifies either variable length decoding or fixed length decoding
for the MSI symbology.
Variable Length:
For variable length decoding, a minimum and maximum length
may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
$CMSCT00
MSI Check Character Transmission = Disable
$CMSCT01
MSI Check Character Transmission = Enable
DEFAULT
$CMSLC00
MSI Length Control = Variable Length
$CMSLC01
MSI = Fixed Length
DEFAULT