Enter/Exit Programming Mode GS1 DataBar
TM
Expanded
128 QuickScan™ I QM21X1 / QBT21X1
GS1 DataBar Expanded Length Control
This feature specifies either variable length decoding or fixed length decoding
for the GS1 DataBar Expanded symbology.
Variable Length:
For variable-length decoding, a minimum length may be set.
Fixed Length:
For fixed-length decoding, two different lengths may be set.
$CXBLC00
GS1 DataBar Expanded Length Control = Variable Length
$CXBLC01
GS1 DataBar Expanded Length Control = Fixed Length