300 QuickScan™ I QM21X1 / QBT21X1
Scanning Active Time
This setting specifies the amount of time that the reader stays in scan ON state
once the state is entered. The range for this setting is from 1 to 255 seconds in
1-second increments.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield three digits. For example: 0 =
000, 5 = 005, 20 = 020, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Program-
ming Mode.
4. Scan the bar code: SELECT SCANNING ACTIVE TIME SETTING.
5. Scan the appropriate three digits from the keypad in
Appendix D, Keypad
,
that represent the duration which was determined in the steps above. You
will hear a two-beep indication after the last character.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming
Mode.
This completes the procedure. See
Table 19
for some examples of how to set
this feature.
Table 19. Scanning Active Time Setting Examples
NOTE
If you make a mistake before the last character, scan the CANCEL bar
code to abort and not save the entry string. You can then start again
at the beginning.
STEP ACTION EXAMPLES
1 Desired Setting
1 Second 90 Sec. (1.5 min.) 180 Sec. (3 min.)
255 Seconds (4.25
min.)
2Pad leading zero(es)
001 090 180 255
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT SCANNING ACTIVE TIME SETTING
5
Scan Three Characters From
Appendix D, Keypad
‘0’, ‘0’ and ‘1’ ‘0’, ‘9’ and ‘0’ ‘1’, ‘8’ and ‘0’ ‘2’, ‘5’ and ‘5’
6 Scan ENTER/EXIT PROGRAMMING MODE