EasyManuals Logo

Dell Command Line Interface User Manual

Dell Command Line Interface
226 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #77 background imageLoading...
Page #77 background image
omconfig: Managing Components Using the Instrumentation Service 77
config=nic
(continued)
ipsource=static | dhcp | systemsoftware static: Static if the IP address of the BMC
LAN interface is a fixed, assigned IP address.
dhcp: DHCP if the source of the IP address of
the BMC LAN interface is the dynamic host
configuration protocol.
systemsoftware: System software if the source
of the IP address of the BMC LAN interface is
from the system software.
NOTE: Not all commands may be supported on
the system.
nicselection=nic1 | teamednic1nic2 |
dracnic
nic1: Enables NIC 1.
teamednic1nic2: Enables NIC teaming
functionality.
dracnic: Enables DRAC NIC if DRAC 5 is
installed.
NOTE: The option nicselection is supported
only on PowerEdge x9xx systems.
privilegelevel=administrator | operator
| user
administrator: Sets the maximum privilege
level that can be accepted on a LAN channel
to Administrator.
operator: Sets the maximum privilege level
that can be accepted on a LAN channel
to Operator.
user: Sets the maximum privilege level that
can be accepted on a LAN channel to User.
subnet=Subnet subnet: Sets a subnet mask if you have
selected static as the IP address source for the
BMC LAN interface.
Table 4-12. omconfig chassis remoteaccess (continued)
name=value pair 1
config=
name=value pair 2 Description

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell Command Line Interface and is the answer not in the manual?

Dell Command Line Interface Specifications

General IconGeneral
BrandDell
ModelCommand Line Interface
CategoryNetwork Card
LanguageEnglish

Related product manuals