6. DESCRIPTIONS FOR TROUBLESHOOTING
E?111 DMCNET packet receiver overflows
Cause
More than 2 packets are received within 1ms.
Check and Correction
Return it to the dealer or original manufacturer for repairing.
Solution
Reconnect power and clear alarm.
E?185 DMCNET Bus hardware abnormal
Cause
DMCNET Bus hardware abnormal or loss of communication packet
Check and Correction
Return it to the dealer or original manufacturer for repairing.
Solution
Reconnect power and clear alarm.
E?201 Initial error of DMCNET data
Cause
Initial error of DMCNET data
Check and Correction
Return it to the dealer or original manufacturer for repairing.
Solution
Reconnect power and clear alarm.
E?235 Position command overflows
Cause
1.
When temporary register for the feedback position overflows;
2.
When the zero return is triggered, but the zero return procedure is not completed;
3.
When E?060 and E?062 occur.
Check and Correction
Implement the zero return procedure.
Solution
Reconnect power and clear alarm.
E?245 Positioning overtime
Cause
Positioning overtime for the position mode .
Check and Correction
Return it to the dealer or original manufacturer for repairing.
Solution
None.
E?283 Drive direct limit
Cause
Exceeding software direct limit.
Check and Correction
Whether the position exceeds the value of P5-09. Please set the limit according
to actual conditions; if the position doesn’t exceed the limit, please set the
maximum:2147483648.
Solution
Reset alarm.

Table of Contents