10. Error messages and trouble shooting
Installation and Operation Manual for RPI M50A
94
Message Possible cause Solution
HW Efciency The calibration is incorrect. Check the accuracy of current and
power.
Current feedback circuit is defective. Check the current feedback circuit
inside solar inverter.
HW NTC1 Fail
HW NTC2 Fail
HW NTC3 Fail
HW NTC4 Fail
Ambient temperature > 90 °C or < -30
°C.
Check the installation ambient and
environment.
Detection circuit malfunction. Check the detection circuit inside
solar inverter.
HW Red ADC1
HW Red ADC2
Insufcient input power. Check the input voltage, must >
150 V
DC
.
Auxiliary power circuitry malfunction. Check the auxiliary circuitry inside the
solar inverter.
Detection circuit malfunction. Check the detection circuit inside the
solar inverter.
HW ZC Fail The detection circuit for synchronal
signal malfunction.
Check the detection circuit for syn-
chronal signal inside the solar in-
verter.
RCMU Fail RCMU is disconnected. Check the RCMU connection inside
solar inverter.
Detection circuit malfunction. Check the detection circuit inside
solar inverter.
Relay Test Open One or more relays are abnormal. Replace the defective relay(s).
The driver circuit for the relay mal-
function.
Check the driver circuit inside solar
inverter.
The detection accuracy is not correct
for V
grid
and V
out
.
Check the V
grid
and V
out
voltage de-
tection accuracy.
Relay Test Short One or more relays are sticking. Replace the defective relay(s).
The driver circuit for the relay mal-
function.
Check the driver circuit inside solar
inverter.
Temperature High The ambient is > 60 °C (the installa-
tion is abnormal).
Check the installation ambient and
environment.
Detection circuit malfunction. Check the detection circuit inside
solar inverter.
Temperature Low Ambient temperature is < -30 °C. Check the installation ambient and
environment.
Detection circuit malfunction. Check the detection circuit inside
solar inverter.