8.16 Constant Q
Overview
With this function you can set a constant reactive power.
This function should be set only when requested by country regulations, authorities or your grid
operator.
Accessing the menu
Main menu > Active/Reactive Pwr > Active Power Ctrl > Constant Q
E-Today: 0kWh
Power: 0W
Status: On Grid
10.Sep 2014 15:32
1. When the default information is displayed, press any button to open the
main menu. Otherwise, repeatedly press the button
ESC
until the main
menu is displayed.
Inverter Info.
General Settings
Install Settings
2. Use the buttons and to select Active/Reactive Pwr.
To con rm your selection, press the button
ENT
.
3. The menu is protected by password 5555. Use the buttons and
to set each digit.
To con rm a digit, press the button
ENT
.
Reactive Power Ctrl
Active Power Ctrl
4. Use the buttons and to select Reactive Power Ctrl. The cur-
rent setting is displayed behind the menu entry.
Constant Q
Cos phi (P)
5. Use the buttons and to select Constant Q. The current setting
is displayed behind the menu entry.
6. To change the mode, use the buttons and to select Mode and
press the button
ENT
.
To switch the function on, select ON and press the button
ENT
.
To switch the function off, select OFF and press the button
ENT
. When
you switch the function off, you can ignore the following steps.
7. If you need to change the parameter Fix Q, use the buttons and
to select the parameter and press the button
ENT
Do not change this setting without prior
consultation with Delta Solar Support.