Preparing for Milling
23
Chapter 2 Milling
Cleaning Tool
You can use the included cleaning tool to clean milling waste away from the machine.
* When using the cleaning tool, you have to congure CAM settings in the same manner as for milling burs.
Materials for Which the Cleaning Tool Is Effective
Zirconia, composite resin, and CoCr sintered metal
Compressed Air (Setting the Regulator)
WARNING
Turn the air pressure adjustment knob slowly and carefully.
Otherwise, the machine may move suddenly, posing a risk of injury.
MEMO
When CAM data is sent to the machine, it automatically adjusts the air pressure
to match the workpiece to mill.
Procedure
Pull up on the upper knob (the air pressure adjustment knob).
Slowly turn the upper knob to adjust the pressure to 0.2 MPa.
When the supply of air starts, the air starts to ow and the pressure drops. When the pressure has dropped, adjust the regulator
to have an appropriate value again. (Air is supplied when the spindle rotates and when the milling bur is replaced.)
Push down on the upper knob.
IMPORTANT!
Be sure to congure the
regulator to 0.2 MPa. Anything
higher may result in a
malfunction. If the pressure is
too low, the desired results will
not be obtained.