Chapter 3 Maintenance
Daily Maintenance
Cleaning after Milling Finishes
After milling nishes, clean the milling area using the included brush or the dust collector. Also clean the milling bur.
Procedure
Clean the inside of the machine.
Use the "Cleaning" dialog box in VPanel to clean the rotary axis unit.
Clean o any milling waste around areas
to in the following gure, as milling waste in these areas may aect the
milling results.
" P. 18 ""Cleaning" Dialog Box"
MEMO
When the machine is in the standby state, opening the front cover and pressing the operation
button will turn on the dust collector. (For dust collectors with a linking function and connected
to the expansion port with a linking cable.)
For details on the dust collector, see the DWX-52D "Setup Guide."
MEMO
With the dust collector operating, use
the included brush to brush off the
milling waste and use the dust collector
to pick up the milling waste.
Especially when it is difcult to remove
the adapter from the clamp, remove the
grime from the area indicated with
.
CAUTION
Do not directly touch
the inside of the ionizer.