67
Chapter 4 Troubleshooting
Machine Trouble
Initial Operations Are Not Performed or Fail
Is the front cover open?
Keep the front cover closed during startup. For safety,
the initial operations are not performed if a cover is
open when the machine starts.
—
Is the milling bur caught on
anything?
The milling bur attached to the spindle unit may fail to
perform the initial operations if it is caught on the work-
piece or rotary axis unit. Try to detach the milling bur
using the emergency release function in VPanel.
P.11
Is anything caught on the spindle
unit or rotary axis unit?
Open the maintenance cover and make sure that no
workpiece or milling waste is caught on these units.
—
The Operation Button Does Not Respond
Is the front cover open?
This machine restricts some operations when the front
cover is open. Close the cover.
—
Are you wearing gloves?
The operation button will not respond if you are wearing
gloves. Operate the button with a bare hand.
—
VPanel Does Not Recognize the Machine
Is the cable connected?
Make sure that the cables are connected.
Refer to the "Setup Guide" ("Connecting the Cable") to
perform the work.
—
Is the driver installed correctly?
If the connection to the computer is not made accord-
ing to the procedure described, the driver will not be
installed correctly. VPanel will not function normally if
the driver is not congured correctly. Check again to
ensure that the connection was made using the correct
procedure.
P.73
Did you verify the connection
procedure when connecting more
than one machine?
There is a possibility that the connection procedure was
performed incorrectly. Make sure that connections were
performed correctly.
Refer to the "Setup Guide" ("Connecting Multiple Units")
to perform the work.
—
Was the machine ID changed?
If the machine's ID has been changed, restart VPanel. P. 5