Periodic Maintenance
62
Chapter 3 Maintenance
Regulator Maintenance (Emptying the Drain)
The regulator is equipped with a lter that becomes lled with drainage (moisture and dust) over time. Periodically empty the drain.
Situations Requiring This Work
When drainage builds up
When the bowl becomes dirty
Procedure
Loosen the lower knob little by little.
Material may spray out of the drain at this time. Use a cloth or the like to catch the spray and keep it from scattering.
After the drain empties, retighten the lower knob.