Operating Manual
© Dürr Systems AG
EcoBell2 SL EC
- Rotating Atomizer with External Charging
Faults
Document No.: MRA00001EN
Version:: 07 As of:: 01/2020
115 / 156
Rinsing result
insufficient
Unsuitable cleaning agent
- Change the cleaning agent
Incorrect turbine speed
- Correct speed (wrong parameter)
Blocked nozzle
- Clean the nozzle
- Replace the nozzle
Turbine
Incorrect speed
Turbine does not reach the set speed
- Bell disk not screwed on the thread
properly
- Bell disk is imbalanced due to a damage
- Inspect the hoses for motor air
- Reflector disk of the turbine is dirty
- Replace the Turbine
Stopping operation takes too long
- The pressure of the break air is
insufficient
- Leaking break air line
Turbine
shaft detent
does not work
Defective shaft detent
- Defective solenoid valve - replace
- Damaged shaft detent - replace
- Replace the turbine