10.2.10 Disassemble Grinder Group
Step 1:(pic.1)First remove the bean holder;
Step 2:(pic.3)press the buckle marked with the red circle to remove the Hall sensor group, and then unplug the wiring
plug on the power board(pic.4)
Step3:(Pic.5)Grab the parts of the grinder by hand, take out the whole grinder group upwards, and disassemble the grinder
group.
★ Attention:
1、Be careful during the disassembly process to prevent scratching your fingers!
4、 Before removing the grinder group, please empty the residual coffee beans and coffee powder in the grinder!