What's new in Evita 4 software 4.n*
Specification of the humidifier used
»Active humidifier«
or
»HME/Filter« (artificial nose)
for more accurate measurement of the volume
parameters
Apnoea ventilation On/Off
can be selected as starting configuration
Extended range of settings for the alarm time
TApnoea >>
>>
from 5 to 60 seconds
(formerly 15 to 60 seconds)
Frequency can be reduced to 0
for BIPAP and SIMV, for weaning without transitions
Ventilation mode BIPAPAssist
for pressure-controlled assisted ventilation
Patient mode »prev. patient« can be selected
to adopt the settings, including alarms, which were
effective before switching off the equipment
Leakage compensation On/Off
for activation and deactivation of the automatic
leakage compensation function
Extended logbook entries
Evita 4.4n identifies alarms which are active but not
displayed with an asterisk
Monitoring of tube blockages
New alarm message »Tube blocked !!!«
Additional weaning parameters
available as software version 4.n plus upgrade
in addition to the parameter occlusion pressure P 0.1
Evita 4.4n also determines the parameters
RSB Rapid Shallow Breathing index
and
NIF Negative Inspiratory Force index
External flow source
available as software version 4.n plus upgrade
The amount of external flow is calculated by Evita 4.4n
(e.g. for additional tracheal gas insufflation) and
adjusts the volume monitoring tolerances in order to
avoid inadvertent alarms
Extended use of loop presentations
available as software version 4.n plus upgrade
Loops can be zoomed and frozen
Loops can be displayed permanently in the upper part
of the screen
Evita Remote (Remote Pad)
optionally available
Remote control pad for parallel remote operation of
function keys on Evita 4
NIV
optionally available
Application mode to support non-invasive ventilation
therapies
Nurse call
optionally available
Connection for transmitting alarm signals to a central
hospital alarm station
* See pages 187 and 188 for new features in software
versions 2.n and 3.n
3
What's new in Evita 4 software 4.n

Table of Contents

Other manuals for Dräger Evita 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dräger Evita 4 and is the answer not in the manual?

Dräger Evita 4 Specifications

General IconGeneral
BrandDräger
ModelEvita 4
CategoryMedical Equipment
LanguageEnglish

Related product manuals