3. WP8010 INSTALLATION
D-306233 CUSDOC PM-10/30 V18 DSC TRIPLE EN INST 59
5.7.3 PGM Output Configuration
Define which factors, including any combination of factors, will determine the PGM output.
Option
Configuration Instructions
PGM: BY ARM AWAY
PGM: BY ARM HOME
PGM: BY DISARM
Determine to activate the PGM output upon arming Away / Home / Disarm.
Options: disable (default); turn ON; turn OFF; activate PULSE.
PGM: BY MEMORY
Determine to activate the PGM output upon registration of an alarm in the memory. The
output will restore to normal upon memory clearing.
Options: disable (default); turn ON; turn OFF; activate PULSE.
Note: In Soak Test
1
mode and when BY MEMORY is enabled, the PGM will not be
activated.
PGM: BY DELAY
Determine to activate the PGM output during the Exit and Entry delays.
Options: disable (default); turn ON; turn OFF; activate PULSE.
PGM: BY KEYFOB
Determine to activate the PGM output upon pressing the AUX () button of keyfob
transmitters configured to activate the PGM output. For further details, refer to the
configuration instructions of the AUX () button of the respective keyfobs' datasheets.
Options: disable (default); turn ON; turn OFF; activate PULSE; toggle
PGM: BY SENSOR
Zone A Z:_ _
Zone B Z:_ _
Zone C Z:_ _
Determine to activate the PGM output upon activation of any one of up to 3 sensors (zones)
in the systems irrespective of whether the system is armed or disarmed.
To configure:
Press to enter the "PGM: BY SENSOR" sub menu and then select the Zone you wish to
program, for example "Zone A". If the zone was configured before, the display shows the
current zone number "(Z:xx)" and if not, the zone number will be blank ("Z:_ _"). To
configure the zone number, press . Enter the Zone number (2 digits) you wish to
activate the PGM output and press to confirm. To add another sensor, select any of
the other two options ("Zone B" and "Zone C") and repeat the above process.
When done press to return.
Options: disabled (default); turn ON; turn OFF; activate PULSE; toggle
Note: If you select toggle, the PGM output will be turned on upon event occurrence in any
of these zones and will be turned off upon next event occurrence, alternately.
PGM:BY LINE FAIL
Determine to activate the PGM output following failure of the PSTN line
Options: by line fail NO (default); by line fail YES.
PGM:BY SIREN
Determine to activate the PGM output as an external wired siren.
Options: disable (default) and ON&OFF by siren.
PGM:PULSE TIME
Determine the PGM output pulse time. This value is the same for all events (by ARM AWAY,
by ARM HOME, by DISARM etc.) which were selected with "activate PULSE" option.
Options: pu lse time 2s (default); pulse time 30s; pulse time 2m; pulse time 4m.
Note: PGM not to be enabled in UL Listed Product.
1
Soak Test is not applicable for UL installations

Table of Contents

Other manuals for DSC WP8030

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC WP8030 and is the answer not in the manual?

DSC WP8030 Specifications

General IconGeneral
BrandDSC
ModelWP8030
CategoryControl Panel
LanguageEnglish

Related product manuals