3. WP8010 INSTALLATION
44 D-306233 CUSDOC PM-10/30 V18 DSC TRIPLE EN INST
Configuration Instructions
the alarm was canceled by the user.
Options: not active (default in USA); in 1/5 (default)/15/60 minute(s) and in 4 hours.
Notes:
1. In some WP8010/WP8030 variants, this menu is displayed in the Operation Mode only (see
section 5.14).
2. To comply with CP-01 requirements, "1 minute" option must not be used. CP-01 features not
to be enabled in UL Listed product.
3. Since the Soak Test
1
zone does not report an alarm event to the Monitoring Station, the
WP8010/WP8030 will not send a “cancel alarm” message to the Monitoring Station even if
disarmed within the Cancel Alarm period.
The WP8010/WP8030 provides you with the following configurable options for resetting the
alarm condition and rearming the system:
By the user as usual - by user (default). By the engineer (installer) by entering and exiting the
"Installer Mode" by entering and exiting the Event Log using the Installer Code or by accessing
the system remotely via the telephone using the Installer Code (by engineer). For accessing the
system via the telephone, see the User's Guide, Chapter 7 – "Remote Control by Telephone" and
use the installer code instead of the user code.
Notes:
1. This feature is not applicable in the USA.
2. This feature is not to be not to be enabled in UL Listed product.
Select the length of time allowed by the system to abort a Fire alarm. The WP8010/WP8030 is
able to provide an “abort interval” that starts upon detection of a Fire event. During this interval,
the buzzer sounds a warning but the siren remains inactive and the alarm is not reported. If the
user disarms the system within the allowed abort interval, the alarm is aborted.
Options: in 00 (default)/30/60/90 seconds
5.5.5 Configuring Sirens Functionality
The following table provides you with a detailed description of each option and its configuration settings. To select an
option and change its configuration – refer to section 5.5.1.
Configuration Instructions
Determine whether the control panel's built-in siren will sound alarms – "ON" (default) or remain
silent – "OFF".
Notes:
1. Panel siren must be enabled unless an external sounder is connected to the product.
2. For UL installations, when set to “OFF” the SR-720 PG2 and SR-730 PG2 sirens must be
connected.
Define the period of time the sirens will sound upon alarm.
Options: 1/3/4 (default)/8/10/15/20 minute(s).
Notes:
1. To comply with EN requirements, the "Siren Time" must not exceed 15 minutes.
2. For Canada, the "Siren Time" must be set to 8 minutes
3. In UL installations, set siren time to 4 minutes min.
Define the length of time the strobe light will flash upon alarm.
Options: 5/10/20 (default)/40/60 minutes.
Determine if the siren will be activated when the phone line fails and the system is armed.
Options: disable on fail (default) or enable on fail.
Soak Test is not applicable for UL installations.