Maintenance work
108 Service Manual 867 Version 02.0 - 04/2015
21.2 Pneumatic system
21.2.1 Setting operating pressure
Proper setting
The operating pressure is 6 bar.
Check the pressure on the pressure indicator every day. The pressure
cannot deviate by more than 1 bar.
Fig. 95: Setting operating pressure
Setting steps
1. Pull the adjustment knob (1) up.
2. Turn the turning handle until the pressure indicator (2) indicates 6 bar:
clockwise: to increase pressure
counterclockwise: to reduce pressure
3. Push the adjustment knob (1) down.
ATTENTION
Machine damage due to incorrect pressure
Incorrect pressure can result in damage to the machine. Make sure that
the machine is only used when the operating pressure is set correctly.
0
2
8
4
6
10
2
1
(1) - Rotary handle (2) - Pressure