Working basis
Service Manual 867 Version 02.0 - 04/2015 15
3.3.5 Opening and closing the throat plate slide
Fig. 5: Opening and closing the throat plate slide
Opening the throat plate slide
1. Press the clamping spring (3) downwards.
2. Push the throat plate slide (1) apart.
Closing the throat plate slide
1. Screw the throat plate slide (1) to the throat plate (2).
3.3.6 Removing and installing the throat plate
(1) - Throat plate slide
(2) - Throat plate
(3) - Clamping spring
WARNING
Risk of injury
Risk of crushing injuries and stab wounds from mov-
ing and sharp parts.
Switch the sewing machine off before you remove
or install the throat plate.