Machines with integrated motor
96 Service Manual 867 Version 02.0 - 04/2015
19.4 Replacing the fuse
The fuse is for the built-in sewing lamp transformer.
Fig. 83: Replacing the fuse
1. Replace the fuse. Value: 0.63 A T.
19.5 Replacing the PCB
Fig. 84: Replacing the PCB
1. Disconnect plugs
2. Undo screws (1) for mounting plate of PCB
3. Replace the PCB (2).
4. Tighten the screws (1).
5. Insert plugs.
Important:
Ensure that the motor is correctly connected.
(1) - Fuse
(1) - Screws (2) - PCB