Winder
Service Manual 867 Version 02.0 - 04/2015 63
5. Fold the winder lever (3) upwards as far as it will go to the thread.
Fig. 50: Setting the winder run and automatic stop
Setting the winder run
6. Loosen the setscrew (8).
7. Set the switch cam (9) such that it is just contacting the leaf spring (10)
when the clamp (5) has engaged in the locking disc.
8. Set the switch cam (9) such that the winder lever (3) has no axial play.
9. Tighten the setscrew (8).
Fig. 51: Setting the winder spacing
Setting the winder spacing
10.Turn the winder spindle (12) such that the tear-off knife (11) is at the
top right and is facing the right-hand screw hole (13).
11.Loosen the setscrew in the clamp (5).
12.Set the winder lever (3) such that the upper arm is above the marking
for the XXL hook (15).
The distance between the winder lever and the outer thread on the
6
8
9
9
0
5
7
(5) - Clamp
(6) - Winder wheel
(7) - Setscrew
(8) - Setscrew
(9) - Switch cam
(10) - Leaf spring
6
^
<
+
5
,
3
(3) - Winding lever
(5) - Clamp
(6) - Winder wheel
(11) - Tear-off knife
(12) - Winder spindle
(13) - Right -hand screw hole
(14) - Locking disc

Table of Contents