Setting the potentiometer
84 Service Manual 867 Version 02.0 - 04/2015
Fig. 67: Setting the potentiometer
6. Check whether the lifting gear plates are flush.
If the plates are not flush:
7. Loosen the setscrews (1).
8. Set the connecting clamp (2) for the lifting cylinder such that the plates
are flush.
9. Tighten the setscrews (1).
10.Loosen the setscrew (3).
11.Turn the potentiometer axle such that the left display shows 1 in the first
instance and the relevant maximum speed next to it.
12.Tighten the setscrew (3) without changing the value shown in the dis-
play.
13.Press the ESC key two times.
Important:
14.Switch off the machine at the main switch.
15.Switch on the machine at the main switch.
Switching off and on will save the setting.
3
4
1
2
(1) - Setscrews
(2) - Connecting clamp for lifting cylinder
(3) - Setscrew for the setting shaft
(4) - Potentiometer