EasyManua.ls Logo

Dynapac CA3500DCP - Replacing the Urea Pump Filter

Dynapac CA3500DCP
178 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance - 2000h
4812165301.pdf2022-09-02
Replacing the urea pump filter
Fig. Urea tank space
1. Urea pump
1
The urea pump is located on the right side of the
machine, beside the urea tank.
The filter is located at the bottom of the unit.
To access the filter, loosen the lid with a 27 mm sleeve
and remove the filter using the tool supplied with the
spare part filter.
Replace with new filter and reassemble the lid with
torque 20 Nm.
Hand in the filter to an environment-friendly waste
disposal station.
Hand in the filter to an environment-friendly waste
disposal station.
165

Table of Contents