Technical specifications
4812165301.pdf2022-09-02
Technical specifications
Vibrations - Operator station
(ISO 2631)
The vibration levels are measured in accordance with the operational cycle described in
EU directive 2000/14/EC on machines equipped for the EU market, with vibration switched
on, on soft polymer material and with the operator’s seat in the transport position.
The vibration levels are measured in accordance with the operational cycle described in
EU directive 2000/14/EC on machines equipped for the EU market, with vibration switched
on, on soft polymer material and with the operator’s seat in the transport position.
Measured whole-body vibrations are below the action value of 0.5 m/s² as specified in Directive
2002/44/EC. (Limit is 1.15 m/s²)
Measured whole-body vibrations are below the action value of 0.5 m/s² as specified in Directive
2002/44/EC. (Limit is 1.15 m/s²)
Measured hand/arm vibrations also were below the action level of 2.5 m/s² specified in the same
directive. (Limit is 5 m/s²)
Measured hand/arm vibrations also were below the action level of 2.5 m/s² specified in the same
directive. (Limit is 5 m/s²)
Noise level
The noise level is measured in accordance with the operational cycle described
in EU directive 2000/14/EC on machines equipped for the EU market, on soft
polymer material with vibration switched on and the operator's seat in the
transport position.
The noise level is measured in accordance with the operational cycle described
in EU directive 2000/14/EC on machines equipped for the EU market, on soft
polymer material with vibration switched on and the operator's seat in the
transport position.
Guaranteed sound power level, L
wA
105 dB (A)Guaranteed sound power level, L
wA
105 dB (A)
Sound pressure level at the driver's ear (platform/ROPS), L
pA
XX dB (A)Sound pressure level at the driver's ear (platform/ROPS), L
pA
XX dB (A)
Sound pressure level at the operator's ear (cab), L
pA
72 ±3 dB (A)Sound pressure level at the operator's ear (cab), L
pA
72 ±3 dB (A)
Electrical system
Machines are EMC tested in accordance with EN
13309:2000 'Construction machinery'
Slopes
Max 20° or 36%Max 20° or 36%
The recommended max slope angle is for a machine
that runs straight on hard, flat surface.
Unstable ground, vibration on, speed and steering the
machine can all cause the machine to topple at
smaller angles than specified here.